A gas water heater that will not stay lit is reporting one of four things: the flame is not proving itself, the gas is not reaching the burner, the air around the burner is wrong, or the control valve has failed. The repair follows from which of those it is, and the checks are the same whether the unit is a tank or a tankless model.
The ignition chain
Thermocouple and flame sensor. The safety device that proves a flame exists. If it sits outside the flame, is coated, or has failed, the valve shuts the gas off within seconds of the pilot lighting. "Lights, then goes out when I release the button" is the classic description.
Igniter. Electronic ignition units use a spark or hot-surface igniter. A cracked igniter or a loose connection produces a unit that clicks or waits without lighting.
Pilot orifice and burner. A blocked orifice gives a weak or yellow pilot that will not hold the sensor. Burner ports can also clog with dust and lint, which shows up as a lazy flame or incomplete combustion.
Gas control valve. The valve regulates and shuts off supply. A failing valve can refuse to open, fail to modulate, or leak internally.
Venting and air
A gas heater needs correct draft. A blocked flue, a sagging vent connector, a flue that back-drafts under wind, or a unit installed in a space without adequate combustion air will produce flame problems that look electrical. Venting is checked as part of any gas repair because a flue fault is also a safety issue.
What the visit covers
Gas supply and shut-off, the ignition chain, the burner and its air, the flue and draft, the tank or heat exchanger, and the relief valve. The finding is explained before parts are recommended, and the unit is checked running before the visit ends.
Repair or replace
Thermocouples, igniters, valves, orifices and flue corrections are all repairs. Replacement becomes the answer when the tank or heat exchanger has failed, when the unit is past its service life and the repair is a large share of a new unit, or when the venting cannot be corrected in the available space.
Safety boundary
A gas smell, a yellow or floating flame, soot around the flue or a back-drafting unit is a stop condition. In those cases the safe action is to shut the unit off, ventilate, and call the gas utility — not to relight it and watch.
Where this runs
The service is offered in Fountain Valley and the six covered communities; each location page sets out the permit authority and access details that apply there.