Gas faults on a hillside are partly a wind story. Del Dios sits in terrain that funnels and accelerates air, and a water heater venting through an exposed wall or a roof termination takes more of that than the same unit would on a flat suburban lot. A pilot that dies on gusty days is a draft symptom before it is an ignition-part symptom.
Draft, not always the thermocouple
The thermocouple is the easy suspect, and it is sometimes right: a coated or mispositioned sensor shuts the gas off seconds after ignition. But when the pattern tracks the weather — fine on still mornings, out after a windy night — the flue and its termination are the place to look.
A termination that is too close to a corner, under an eave, or exposed to the prevailing upslope wind can pull air down the flue instead of letting exhaust rise. The repair is a vent correction, not another sensor.
Long runs and pressure
Outbuildings and detached garages here are often at the end of a long, small gas line. A run that was adequate for a stove can be marginal for a water heater's input, and the result is a weak, lazy flame that will not hold the sensor. Measuring pressure at the appliance separates a supply problem from a valve problem before anything is replaced.
The ignition parts, in context
- Thermocouple or flame sensor — proves the flame; fails when coated or out of position.
- Igniter — sparks or heats; cracks and corrodes on exterior units.
- Pilot orifice — blocks with dust and insects; gives a weak pilot.
- Gas control valve — regulates and shuts off; fails less often than it is blamed.
Venting and the fire zone
Del Dios is a Wildland-Urban Interface community, and exterior equipment placement is checked with that in mind. Vent terminations, clearance from vegetation and access for inspection all matter, and a repair is a reasonable moment to look at them.
What the visit covers
Gas pressure and shut-off, the ignition chain, burner and air, the flue and termination, the tank and relief valve. The fault is identified and explained before parts are quoted.
The safety line
A gas smell, soot at the flue, a yellow or lifting flame, or a perforated vent connector: shut the unit off and stop. Those are not faults to monitor.