A tankless unit heats on demand, so its failures show up as performance rather than as a tank of cold water: a code on the display, water that alternates hot and cold, ignition that never happens, or a flow that drops to a trickle. The first step is reading the unit rather than guessing at it.
Error codes
Every manufacturer uses its own code set. A code does not name the failed part; it names the circuit that reported a fault — ignition, flame proving, airflow, water flow, outlet temperature. With the model number, the code points at a short list of checks, and those checks decide the repair.
Hot, then cold
The "cold water sandwich" pattern has three common explanations:
- Scale in the heat exchanger restricts transfer, so the unit cannot hold the set temperature under load.
- A flow sensor misreads the demand and the unit modulates wrongly.
- Undersizing shows up when a second fixture opens — the unit was installed for one shower, not two.
Descaling addresses the first. The other two need the installation and the unit’s rating checked against the actual demand.
Scale and descaling
Hard water is the main enemy of a tankless heater. Calcium collects on the exchanger walls, raising the temperature needed for the same output until the unit derates or shuts down. Descaling — circulating a descaling solution through the service valves — removes it. In a very hard-water area this is the scheduled service that keeps the unit working, not an optional add-on.
Ignition, airflow and water flow
Gas tankless units need gas, air and water in the right proportions. A dirty flame sensor, a blocked intake, a failing blower or a restricted inlet filter each produce ignition or shutdown faults. Water-side faults show as low flow, a noisy exchanger or a unit that shuts off mid-use.
What the visit covers
The code history, gas supply and pressure, the intake and exhaust, the flame sensor and igniter, the water filter and flow sensor, the exchanger condition and the relief valve. Findings are explained before parts are recommended.
Service valves and maintenance
A tankless unit without service valves cannot be descaled without extra work. Where they are missing, fitting them is worth doing at the first service — it is the difference between a routine descale and a dismantling job.