A storage tank in this city is asked to do two difficult things: heat very hard water, and do it inside buildings where the supply is often closed by a pressure-reducing valve or a backflow preventer. The first produces scale; the second produces pressure complaints that get misdiagnosed as valve failures.
Scale, and the sound it makes
Calcium and magnesium come out of solution when the water is heated. In Solana Beach the supply is hard enough that the layer on the tank base forms quickly, insulating the steel from the water above it and trapping a film that boils as the burner cycles.
That is the popping. Flushing clears the loose deposit. A tank that has gone years without it may hold a hardened layer a simple flush will not shift, and an aggressive attempt on a thinned old tank can open a leak that was already close.
The anode, and rusty water
The anode rod is sacrificial: it corrodes so the shell does not. When it is consumed the tank becomes the anode, hot water turns rusty and the lining begins to fail. Replacing the rod in time extends the tank's life; replacing it after corrosion has begun does not.
Pressure in a closed building
Many condominium buildings and some houses have a check valve, a pressure-reducing valve or a backflow preventer on the supply. Water expands as it heats and, with nowhere to go, the pressure rises until the temperature-and-pressure relief valve discharges.
A dripping relief valve in that situation is not a failed valve. It is a system without expansion control, and the answer is a correctly sized expansion tank on the cold side. Replacing the valve alone guarantees the symptom returns.
Valves and controls
The relief valve is tested at service and replaced if it will not reseat. The drain valve fails on its own schedule: plastic bodies split, old brass ones seize. On a gas unit the flue and burner are checked; on electric, elements and thermostats.
When the tank is finished
A shell leak at a seam or the bottom head, a base rusted through, or a unit past ten years whose next repair is a large share of a replacement. Until then, the tank can usually be kept — with a flush schedule that this water makes necessary rather than optional.