Electric tanks in this town live in two kinds of building. There are the cottages and small houses where the heater sits in a garage or a hallway closet, and there are the condominium buildings where it sits in a mechanical room, sometimes several floors from the unit it serves, on a circuit that is labelled somewhere else entirely.
That second arrangement is where most of the difficulty is. The electrical fault is usually simple; finding the isolation point and confirming which unit the tank serves is the part that takes a phone call.
What the symptom tells you
Cold at every tap. Power is confirmed at the unit first, then the high-limit switch and upper thermostat. A tripped limit means something overheated, so the switch is not the fault.
Warm, then cold. One of two circuits has failed. The upper element heats the top of the tank; without it the lower never switches in.
Warm throughout, never hot. A lower element, a thermostat that has drifted, or heavy scale on the element sheath preventing heat transfer.
Breaker trips when the tank runs. A grounded element is the usual cause, followed by a corroded terminal and a tired breaker.
The coastal wear pattern
Marine air gets into exterior closets and garage corners, and it attacks element terminals, thermostat contacts and wire ends. The result is resistance where there should be none: heat at the connection, nuisance trips, and elements that fail earlier than their rating suggests. When a terminal is corroded, cleaning and remaking the connection is part of the repair, not a detail.
Scale, and why it matters to the element
The Santa Fe Irrigation District supplies this city, and its water is very hard. Scale coats the element sheath, the element runs hotter than designed for the same output, and it fails sooner. A tank that produces lukewarm water with every component testing correctly is usually a scaled tank, not a failed part.
Working inside a condominium
Two practical points: identify the circuit and its isolation before work begins, and confirm whether the heater serves one unit or several. In a building, the second answer decides who authorises the repair.
When repair is not the answer
A leaking shell, a base corroded through, or a second failure on a tank past ten years. Elements and thermostats are inexpensive; a tank that has begun to leak is not repairable at all.